When running any regulatory test, a user mode application could interfere with the test. For example, an application could request a channel scan from the radio while the radio is performing a continous transmit test. When this occurs, the radio may crash or stop transmitting resulting in a short burst of data. To prevent such interference, disable all daemons and applications not required to run the regulatory test.

The following table shows some user mode applications that must be disabled for the lru to operate properly.

Application Mitigation
Network Manager killall NetworkManager
WPA Supplicant killall wpa_supplicant
WPA Supplicant killall sdcsupp
hostapd killall hostapd